Troubleshooting guide › Process troubleshooting › TIG welding problems

TIG welding problems: tungsten, arc starting, gas, black welds and contamination

TIG is the cleanest process and the least forgiving. The tungsten, the gas cover and the cleanliness of the joint decide the result, and the machine can only help. This page covers the machine-side faults (arc starting, HF, gas valve) and the technique faults (contamination, wandering arc, grey welds) in one place, so the operator can tell which is which.

Seen with: DC TIG on steel and stainless; AC TIG on aluminium; HF or lift arc start; air-cooled and water-cooled torches.

Reviewed by the Cruxweld technical team, October 2026. Settings are starting points to confirm on a test piece; acceptance is decided by the code or drawing the job is built to. Checks marked “call” are for our technical team.

Before you start: Switch off and isolate the machine before touching any cable, feeder or torch connection. Anything inside the cabinet is for our technical team, not the operator. HF arc starting produces high voltage at the torch; keep the torch away from electronics and from your body when the trigger is pressed.

Arc will not start

SymptomLikely causeWhat to do
No HF crackle from the machine when the trigger is pressedTorch switch or its socket faulty or not plugged in; remote/pedal selector in the wrong positionCheck the trigger plug and the panel selector (torch / pedal); try the other
HF crackles, no arcTungsten too far from the work (keep 2-3 mm); tungsten blunt, broken or poor quality; dirty work; current set very lowBring the tungsten to 2-3 mm, regrind to a point, clean the work, raise current
HF crackles, no arc, machine recently overheatedOver-temperature or over-current protection activeLeave switched on for a few minutes; weld when the lamp goes out
Arc starts only with a scratchHF spark gap dirty or out of adjustment; HF off in lift-arc modeSelect HF mode; the spark gap is set by our technical team
HF will not switch off after the arc startsTorch switch shorted or trigger cable damagedCheck the torch lead and trigger
Arc starts but current cannot be adjustedCurrent control or pedal fault; machine in the wrong mode (pedal connected but panel set to torch)Check mode and the pedal plug
Arc starts, weld blows out, no gasCylinder closed or empty; solenoid not opening; hose blockedSee gas below

Lift-arc start (touch the tungsten, lift) is for machines or jobs where HF would interfere with nearby electronics or CNC controls. It works well on steel; on aluminium HF is preferred to keep the tungsten clean.

Tungsten: choosing, grinding, when it is contaminated

TungstenUseTip for DCTip for AC
2 % lanthanated (blue)All-round: steel, stainless, aluminium on invertersSharp point, 20-30 degree included angleSlightly blunted point; a small ball forms
2 % thoriated (red)DC steel and stainless; avoid grinding dustSharp pointNot for AC
2 % ceriated (grey)Low-current DC, thin stainlessSharp pointNot usual
Zirconiated (white) / pure (green)AC aluminium on transformer machines–Balled end
Tungsten diameterDC current rangeAC current range (balanced)
1.0 mm15-80 A20-60 A
1.6 mm70-150 A60-120 A
2.4 mm150-250 A100-180 A
3.2 mm250-400 A160-250 A
4.0 mm400-500 A200-320 A

Typical ranges for lanthanated tungsten with argon. AC ranges depend on balance; more cleaning (EP) time needs a thicker tungsten.

  • Tungsten inclusion is different from a contaminated tungsten: a piece of the electrode broke off into the weld (dipped tungsten, too much current for the size, a cracked tip from grinding across the grain, or a tungsten that touched the filler). It shows as a bright white spot on a radiograph and is rejected on code work; grind it out, regrind the tungsten and reduce current or use a larger size.
  • Grind lengthwise, so the grinding marks run along the tungsten, not around it. The taper should be 2-3 times the diameter long for DC.
  • A tungsten that touched the pool or the filler is contaminated: the arc turns bluish, wanders, and the weld goes dirty. Stop, snap off the contaminated end, and regrind.
  • A tungsten that balls up or melts on DC is being run above its current range, or the torch is on the wrong polarity (TIG is DC-, torch to negative).
  • Stick-out: 3-5 mm past the cup for butt welds, up to 8 mm for fillets and corners with a gas lens.
  • Match the collet and collet body to the tungsten diameter; a loose collet overheats and the arc wanders.

Grey, black or dirty welds

1Gas flow too low or none

Argon below 5 L/min does not cover the pool; the weld oxidises and goes grey or black.

Fix: Set 6-10 L/min for a size 6-7 cup, 10-15 L/min with a gas lens and large cup. Check gas flows from the nozzle, not just at the regulator.

2Cylinder nearly empty or valve closed

Flow drops as the pressure falls below about 5 bar.

Fix: Change the cylinder; keep the valve fully open.

3Gas leak or blocked path

A split hose, a loose torch connection, or coolant leaking into the gas line.

Fix: Soapy water on every joint; check the torch body O-rings; replace a cracked gas hose.

4Post-flow too short

The weld end and the tungsten are still hot when the gas stops; both oxidise.

Fix: Post-flow 1 s per 10 A, minimum 5 s. The tungsten should stay silver after the weld.

5Draught

Argon is heavy and easily blown away.

Fix: Screen the job; never TIG near a fan.

6Dirty base metal or filler

Oil, paint, marker ink and moisture burn into the pool.

Fix: Degrease, grind bright, wipe the filler rod with a clean cloth. Use dedicated stainless brushes for stainless and aluminium.

7Contaminated tungsten

A tungsten that touched the pool carries steel into every weld.

Fix: Regrind.

8Gas purity

Industrial argon below 99.99 % or a contaminated cylinder.

Fix: Use welding-grade argon; try another cylinder before blaming the machine.

Wandering, unstable or flaring arc

  • Tungsten blunt, contaminated or ground round-the-circumference: regrind lengthwise to a point.
  • Current too low for the tungsten size: the arc hunts around a cold tip. Use a thinner tungsten or more current.
  • Tungsten too far from the work: hold 2-3 mm.
  • Arc blow near corners or magnets: see the arc blow page.
  • On AC aluminium: raise the AC frequency (80-120 Hz) for a narrower, stiffer arc.
  • Collet loose or wrong size: the tungsten is not making good contact in the torch.
  • Mains or interference: a wobbling current reading points to the supply, not the torch.

Gas problems

SymptomLikely causeWhat to do
No gas when the trigger is pressedCylinder valve or flow meter closed; hose blocked or crushed; solenoid valve or its relay faultyOpen both valves; check the hose end to end; if the solenoid does not click, call service
Gas flows all the timeSolenoid stuck open or trigger shortedCall service; do not leave the cylinder open overnight
Flow meter reads but no gas at the nozzleTorch body leak, split torch hose, blocked gas lensReplace the hose or gas lens
Porosity at the start of the weldPre-flow too shortSet 0.5-1 s pre-flow; purge the line after changing cylinders
Weld black at the endPost-flow too shortSee above

Machine protection and power faults

  • Yellow over-temperature lamp on, no output: leave the machine on so the fan runs; weld again when the lamp goes out. If it happens every few minutes, the job exceeds the duty cycle or the air inlets are blocked.
  • Fan does not run at switch-on: on many machines the fan starts only when welding begins. If it never runs, the machine will overheat; call service.
  • Rated current not reached: supply voltage low, input cable too thin, or a single-phase machine on a weak line. Check supply under load.
  • Machine in protection as soon as it is switched on: wrong supply (a 230 V machine on 415 V), or a mains over-voltage. Switch off and check the supply before anything else.
  • Pulse, slope or AC settings not taking effect: check the mode selected (2T / 4T, DC / AC, pulse on) before suspecting a fault.

Typical DC settings, stainless or mild steel, argon

1 mm sheet1.6 mm tungsten, 1.0-1.6 mm filler, 30-50 A, 6-8 L/min
2 mm1.6-2.4 mm tungsten, 1.6 mm filler, 60-90 A, 7-9 L/min
3 mm2.4 mm tungsten, 1.6-2.4 mm filler, 90-130 A, 8-10 L/min
5 mm2.4-3.2 mm tungsten, 2.4 mm filler, 140-200 A, 10-12 L/min
8 mm3.2 mm tungsten, 3.2 mm filler, 200-280 A, 12-15 L/min, water-cooled torch
Pulse (thin sheet)Peak = set current, base 30-50 %, 1-3 Hz, 40-50 % on time
Down-slope / post-flow2-5 s / 8-15 s

Starting points. Stainless runs about 10 % lower current than mild steel. For aluminium see the aluminium guide.

Prevention checklist

  • Grind tungsten lengthwise; keep a spare ground and ready.
  • Gas checked at the nozzle before the first weld; post-flow set.
  • Joint and filler degreased and bright; dedicated brushes.
  • Collet and cup matched to the tungsten; gas lens for stick-out over 5 mm.
  • Torch and earth cables tight; HF kept away from electronics.
  • Water-cooled torch: coolant level and flow checked daily.

Questions we get asked

Why does the tungsten go black after every weld?

Post-flow is too short or the gas flow is low, so the hot tungsten oxidises in air. Set post-flow to 1 s per 10 A and check the flow at the cup.

Can I TIG weld with the torch on positive?

No. DC+ on TIG puts most of the heat into the tungsten and melts it in seconds. The torch always goes to negative for DC TIG; AC alternates automatically.

What does the gas lens do?

It replaces the standard collet body with a screened one that gives a smooth, laminar gas column. It allows a longer stick-out and a lower flow, and it is the first thing to fit when welding stainless corners or titanium.

Do I need a water-cooled torch?

Above about 200 A for more than a few minutes, or on long production seams, yes. An air-cooled torch run at its limit overheats the handle and the tungsten, and the operator slows down.

Fix it yourself: your Cruxweld machine

Lamps, fault codes and the checks an operator can do outside the cabinet, for the machines this page applies to.

Does the machine matter?

A DC TIG with HF start, adjustable post-flow, down-slope and pulse covers steel and stainless. Aluminium needs AC with adjustable balance and frequency. Above about 200 A continuous, or on long seams, a water-cooled torch with a cooling unit stops the torch overheating and lets a smaller, more controllable tungsten run at full current.

Still stuck?

Send a photo of the weld or cut, your machine model, consumable and plate thickness. Our technical team replies on WhatsApp with the likely causes and the next checks to make.

45+ years of welding expertise · GeM Registered OEM Manufacturer · Supported Worldwide

WhatsApp chat