Troubleshooting guide › Fix it yourself, by machine › CSW submerged arc machines

Fix it yourself: Cruxweld CSW submerged arc machines (CSW630i, CSW1000i, CSW1250i) and tractor

The CSW machines show a fault code on the display when something is wrong, which removes most of the guessing. This page lists the codes, the protections that look like faults (wire-touch protection, the 20-second auto-stop), the tractor faults, and the checks that clear them. For bead problems, see the submerged arc process page.

Covers: CSW630i, CSW1000i, CSW1250i (FLUXOR 1000 / 1250) with welding tractor and control box; column-and-boom mountings.

Reviewed by the Cruxweld technical team, October 2026. Settings are starting points to confirm on a test piece; acceptance is decided by the code or drawing the job is built to. Checks marked “call” are for our technical team.

Before you start: Switch the machine off at its own switch and at the distribution box before touching any cable, torch or connection. Everything on this page is outside the cabinet: supply, cables, consumables, gas, air, water and settings. If a check below does not clear the fault, stop there and send us the symptom; opening the machine is for our technical team. The tractor moves on its own in auto mode; keep hands away from the wheels and the wire feed rolls.

Fault codes and protections

Code or behaviourMeaningWhat to do
E19Thermal protection: ambient over 40 degrees C, fan failure, or the temperature relayLet the machine run off-load until it clears; check the fan is turning and the louvres are clear; if it returns at low load: call
E43Communication failure between machine and control box: loose or broken control cable, or the overload protector on the panel tripped (feeder or carriage motor overcurrent)Reseat both ends of the 14-core control cable; find why the motor overloaded (wire jam, wheel blocked); reset the overload protector
E18Head feedback line disconnected: voltage feedback wire broken, or the positive output cable not connectedCheck the feedback lead from the head and the positive cable at the machine
E70Short circuit when switching from SAW to MMA mode: the torch or the head is touching the workLift the head clear of the work, then switch
Wire will not feed down while it touches the workWire-touch protectionLift the wire clear, or hold the feed / retract switch for more than 3 s to override
Welding stops about 20 s after Start with no arc, or 20 s after the arc is lostAutomatic shutdownCheck the tip, the earth and the wire contact; restart
Fan runs only while welding and stops a while afterNormalNothing

Power source faults

What you seeCheck yourselfIf it persists
No display after power-onSupply phases; the internal 3 A fuse (user-accessible on the rear on most units)Breaker, board or transformer: call
Breaker trips immediately at switch-onNothing outsideCall; do not keep resetting
Machine does not work, display onSupply phases, fuse, control cable, fan runningRelay or board: call
Parameters cannot be adjustedEncoder knob loose; display board on the machine or the trolley boxCall
Welding current unstablePhase loss; supply sagging at peak hoursRectifier, current sensor or board: call
Welding voltage unstableContact tip burnt; feed roller worn or not pressed; earth contact poor; earth cable too longReplace the tip; set the roller; shorten and clean the earth; then call

Tractor and control box faults

What you seeCheck yourselfIf it persists
Tractor will not startStart button; 14-core control cable at both ends; power source runningControl box board: call
Travel unsteadyTravelling wheel loose; clutch slipping; track or plate dirty; hoses draggingClutch: call
Difficult arc startingContact tip burnt; wrong wire diameter selected on the panel; stick-out (bring the wire to 3-5 mm from the plate); wire end cut sharpCall
Slow wire feed only after startNegative cable contactSource: call
No wire feed or no travelMechanical jam; toggle switch; motor brushesMotor or board: call
Current out of controlControl cable damageMachine fault: call
Flux does not flowHopper empty; nozzle or hose blocked with slag lumps; damp flux cakingClean the hopper and hose; dry the flux

Daily and weekly care

  • Daily: contact tip, feed roller pressure and groove, flux hopper clean and topped up, earth clamp bright and tight, control cable plugs seated.
  • Daily: tractor wheels and track clean of flux and slag; hoses looped and supported.
  • Weekly: blow dust from the louvres (isolated); check cable lugs for heat; sieve recovered flux.
  • Keep the flux in a heated hopper or a sealed bag; re-dry as the flux maker specifies.

Questions we get asked

E43 keeps coming back

The overload protector trips when the feeder or carriage motor draws too much: a wire jam, a worn liner, a wheel fouled by slag, or a dragging hose. Fix the drag, not the protector.

Flat or drooping characteristic?

Flat (CV) for wire up to 3 mm, drooping (CC) for 3 mm and above. The wire diameter selector must match the wire fitted, or arc starting is poor and the bead wanders.

Models covered on this page

Open your model for its specifications; the spares page lists the consumables for it.

Welding or cutting problem rather than a machine fault?

If the machine runs but the weld or cut is wrong, the cause is usually settings, consumables or the material. Start here:

Does the machine matter?

The SAW power source runs at 100 % duty for hours; its enemy is heat and a sagging supply. Keep the louvres clear, the ambient reasonable and the supply cable sized for the full current, and E19 stays off.

Still stuck?

Send a photo of the weld or cut, your machine model, consumable and plate thickness. Our technical team replies on WhatsApp with the likely causes and the next checks to make.

45+ years of welding expertise · GeM Registered OEM Manufacturer · Supported Worldwide